SK3000 Operator’s Manual Maintenance - 79
Procedures
Procedures
Battery
Radiator/Hydraulic fluid cooler
Track tension
Corrosive fluid. Contact can cause death or serious injury.
Avoid contact. Wear appropriate gloves. See Safety Data Sheet (SDS) for
more information.
To help avoid injury:
• Never attempt to charge a battery that is leaking, bulging, heavily corroded, frozen, or otherwise
damaged.
• Refer to Safety Data Sheet (SDS) for additional information regarding battery.
Explosive hydrogen gas. Fire or explosion can cause death
or serious injury. Keep heat flames, sparks, and other sources of ignition
away.
To help avoid injury:
• Use a single 12V maximum source for charging. Never connect to rapid chargers or dual batteries.
• Never lean over battery when making connections.
• Never allow vehicles to touch when charging.
• Never short-circuit battery terminals for any reason or strike battery posts or cable terminals.
• Refer to Safety Data Sheet (SDS) for additional information regarding battery.
Service
Startup
10 Hours
50 Hours
250 Hours
500 Hours
1000 Hours