8
IP1854EN - 2013-03-01
6.3 Jumper
6.4 Signals
Jumper Description OFF ON
JR4 Overtravel reduction.
Reduces the overtravel distance for the
door wing.
Disabled.
NOTE: set JR4=OFF is the motor is equip-
ped with an electric brake.
Enabled.
NOTE: preferably set JR4=ON if the door
wing performs an excessive overtravel.
JR6 Application type. Sliding gate. Other applications.
NIO Electronic antifreeze system. Maintains
motor function even at low ambient tem-
peratures.
NOTE: for correct operation, the control
panel must be exposed to the same am-
bient temperature as the motors.
Enabled.
ATTENTION: do not use with LOGICMJ.
Disabled.
JR10 Maximum power at start. Disabled.
The motor starts with the voltage set with RF.
Enabled.
The motor starts at maximum power for 1 s.
OM Automation type. One motor automation (M1 only). Automation with two independent motors.
D5 Step-by-step sequence. Open-stop-close-stop-open. Open-stop-close-open.
S5 Step-by-step sequence stop duration. Permanent.
(Automatic closing disabled).
Temporary.
(Automatic closing enabled).
JT Closing operation time. Set with TM+4 s.
NOTE: set JT=OFF with hydraulic or friction
gearmotor.
Automatic.
EO Electric lock function. Powered with automation closed. Powered for 1 s at the beginning of the
opening operation.
SO Reversal safety switch func-tion. With automation stopped and contact 41-8
open, opening operations are permitted.
With automation stopped and 41-8 open, all
operations are disabled.
LED On Flashing
POWER
24 V power supply /
SA
Indicates that at least one of the safety contacts is open. Safety test failure (terminal 41).
Operations count performed (only when control panel is switched
on):
= 1000 operations
= 10000 operations
IN
Activated at every command and adjustment to the dip-switch
and jumper.
/
11
Indicates that the 0-11 limit switch contact is open.
/
12
Indicates that the 0-12 limit switch contact is open.
/