EasyManua.ls Logo

Dixie Narco 501E - Major Component Description; Electrical Components; Refrigeration Components

Dixie Narco 501E
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAJOR COMPONENT DESCRIPTION
24
ELECTRICAL
Transformer Provides 24 volt and 12 volt
power to the Machine
Controller
Fuse (F1) 1.6 Amp Slo Blo
Control Board Power
(includes display and MDB
Peripherals)
Fuse (F2) 6.0 Amp Fast Blo
Vend Motor Power
Relay Potter & Brumfield
T91P5D52-24
240VAC/20A-NO/10A-NC
(Compressor, Light, Fan)
Power Line Filter
Schaffner (HT2)
FN2020-6-06
110/250VAC / 50-60 Hz
6A@40
0
C / -25
0
C +85
0
C
Choke Foster (HT3)
A-16015
5mH 6A
REFRIGERATION
110 VAC
Compressor Embraco, 1/3 HP, 115
VAC, 60 Hz
1 Phase
Unit uses 7.5 oz. of 134A
Refrigerant
Start Relay
110 VAC, 1.351.605
Start Capacitor 110 VAC
233-280 MFO / 165V
Thermal
Overload
110 VAC
MRT 22AF2-5598
Condenser Fan 6W Motor
110 VAC
FV870CW25S
Blade 8-
11
/
16
” dia.
Evaporator Fan 6W Motor
110 VAC
AD775CW32S
Blade 8-
3
/
4
” dia.

Table of Contents