Airspeed:
Range: from 0 to 850 knots. Optional: 0 to 1,000 knots.
Resolution:
standard: 1 knot below 50 knots;
0.1 knots above 50 knots;
Ultra-Low Speed: 1 knot below 20 knots;
0.1 knots above 20 knots.
Accuracy: ± 0.8 knots @ 50 knots;
± 0.1 knots above 500 knots.
Airspeed rate:
Range: from 0 to 500 knots/min.
The maximum value depends on the volume of the pneumatic load.
Resolution: 10 knots/min.
Accuracy: ± 10 knots/min ± 1% of reading.
Angle of attack (Pd2 differential pressure):
Range: from -2.5 to +2.5 inHg (-85 to +85 hPa).
Resolution: 0.001 inHg, 0.01 hPa.
Accuracy: ± 0.003 inHg (0.10 hPa).
Mach number:
Range: from 0 to 6 (limited by airspeed range).
Resolution: 0.001.
Accuracy: ± 0.002 @ sea level.
2.2.3 POWER
90 to 240 VAC and 50 to 400 Hz.
Maximum power consumption: 120 W.
Optional 28V DC (option A0) with cable “CBL110929GPA”.
An internal battery is included, providing 2 hours operation.
Maximum current output from the Encoding Altimeter connector (option B7):
24V line (pins 1, 2): 300 mA;
5V line (pin 5): 500 mA.
2.2.4 PRESSURE MEDIA
Air
2.2.5 MEASURE UNITS
The operator can change the default units as required. Upon request, DMA can deliver the
ADTS with different default units.
Default Units are: feet, knots, hPa.
The following additional aeronautical and pressure units are available by pressing the
appropriate key: