CellCom‑LTE‑V
Programming and Installation Guide Digital Monitoring Products
23
TIME CHANGES
Choose YES to allow the communicator to request automatic time changes from the
SCS‑1R or SCS‑VR receiver. The receiver must be programmed to send and receive time
change updates from the host computer at least every 24 hours. The default is YES.
Choose NO to disable automatic time change requests.
When time zone is programmed YES, enter the number (0‑23) that indicates the
Greenwich Mean Time zone (GMT) where the communicator is located. The default is 6.
See Table6 for GMT values.
GMT City/Time Zone GMT City/Time Zone
0 London, Monrovia, Lisbon 12 Fiji, Marshall Island, Wellington
1 Cape Verde Island, Azores 13 New Cadelonia
2 Mid‑Atlantic 14 Guam, Sydney
3 Buenos Aires, Georgetown 15 Tokyo, Seoul
4 Atlantic Time (Canada), Caracas 16 Hong Kong, Singapore
5 Eastern Time (US, Canada) Bogota 17 Bangkok, Hanoi
6 Central Time (US, Canada) Saskatchewan 18 Dhaka, Almaty
7 Mountain Time (US, Canada), Edmonton 19 Islamabad, Karachi
8 Pacific Time (US, Canada), Tijuana 20 Abu Dhabi, Kazan
9 Alaska 21 Moscow, Bagdad
10 Hawaii 22 Eastern Europe
11 Midway Island, Samoa 23 Rome, Paris, Berlin
KEYPAD INPUT
Select ECP to enable communication between the communicator and an Ademco/
Honeywell panel using the +Z4‑ terminals. Using the Ademco/Honeywell ECP Bus, the
communicator can add, delete, and change user codes as well as arm and disarm the
Ademco/Honeywell panel. The communicator will forward alarm messages from the
Ademco/Honeywell panel to the central station.
Select NONE to allow zone4 to function as normally programmed. The default is NONE.
See Ademco/Honeywell ECP Connection for examples of panel wiring and necessary
Ademco/Honeywell panel programming.
TIME CHG NO YES
HRS FROM GMT: 6
KYPD INPUT
NONE ECP
Table 6: GMT Time Zones

Other manuals for DMP Electronics CellCom LTE-V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics CellCom LTE-V Series and is the answer not in the manual?

DMP Electronics CellCom LTE-V Series Specifications

General IconGeneral
BrandDMP Electronics
ModelCellCom LTE-V Series
CategoryCell Phone
LanguageEnglish

Related product manuals