DESCRIPTION
2-6 20509 Issue 7 Jan 2018
Environment
Electrical Requirements
Supply Fuse Rating
Inputs
External Alarms
Temperature Range
(Operating):
+5º to +40ºC (42ºF to 104ºF)
Humidity: 10 - 90% RH (non-condensing)
Supply Voltage: 110V, 130V, 150V, 220V, 240V, 260V, single
phase with ground.
Power: 300VA
Supply frequency: 50/60Hz
Power switch: 2A (220-260V)
4A (110 - 150V)
Product Detector: 12V, 100mA dc supply to sensor, 5 pin AXR
connector.
Shaft Encoder (print rate
control):
suitable for open collectors or TTL encoders.
Encoder power supply link selectable, +5V
or +12V. 5 pin AXR connector.
Data Interface: RS232 or 20mA current loop
75-19,200 Baud, selectable.
One output via changeover
relay contacts:
2.5A at 260V max. Non inductive.