3.1 Entry Lane Only
SECTION 3 - LOOP DETECTOR LANE SETUPS
Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF
position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a
licensed electrical contractor perform this work.
Loop detector wiring shown is for DoorKing model 9409 Dual Channel, 9410 Single Channel and 9411 Single Channel with
Aux Relay plug-In loop detectors only.
If using other loop detectors refer to the separate Loop Information Manual for installation instructions, loops/preformed
loops and wiring diagrams.
Speed Bump
Dual Channel
REVERSE
SENSITIVITY
TIME
DELAY
SW 1
SW 2
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC NO
UP
LOOP
DOWN
LOOP
123456 789 10 11 12 13 14
1601
Down Loop
Arming Loop
for Access
Control Device
(Optional)
Access
Control
Device
Pedestrian Photo Sensor
Com
Com
Com
Reverse
NO
NC
Jumper
Loop 1
Com
NO
SW 1
SW 1, switch 4 is ON.
SW 1, switch 7 is OFF (Timer). The arm
will rotate down after the vehicle clears
the down loop. See timer note below.
A
A
Helps increase distance
and time between vehicles.
1
ON
2 3 4 5 6 7 8
Main Terminal
12 Ft.
Single Channel
with Aux Relay
Pedestrian Photo Sensor Note: Photo sensor must be installed to protect
pedestrians from the lowering arm. When connected as shown, the photo
sensor will only cause an arm reversal when a vehicle is not present on the
down loop. When a vehicle is present on the down loop, the photo sensor
has no affect on the barrier arm operation. A down loop MUST be installed
directly under the arm for the pedestrian photo sensor to function.
Arming Loop Note: The arming loop only allows the access control device to
function when a vehicle is on the loop, otherwise it will not function. This
prevents pedestrians from gaining access through the vehicular gate.
Timer Note: The timer can be used with a down loop. When timer is ON with
a down loop, it will start countdown when the arm has fully raised. Activation
of the down loop will cancel timer countdown. Useful when an access
control device has been activated but vehicle does not move forward to
activate the down loop. The arm will remain UP. Timer will time out and
lower the arm without the down loop being activated.
Type of wiring to be used on ALL external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better electrical,
mechanical, and flammability ratings.