20
air pressure of the alarmed wheel position and the words LOW PRESSURE until the
problem is corrected. If the alarm comes on and the FAST LEAK icon appears (see Figure
4-2), this means the tire is losing air at a rate faster than 4.5 PSI in a 16 second period.
The FAST LEAK icon will only be displayed when a fast leak is detected and will go out
when the air quits leaking from the tire. We strongly urge you to pull over and inspect the
possible tire damage immediately.
When the low pressure light illuminates, STOP and check your tire(s) as soon as
safely possible, and inflate them to the proper pressure.
Driving on a significantly under-inflated tire can cause the tire to overheat and lead to tire
failure. Under-inflation also reduces fuel efficiency, tread life, potentially affecting the
vehicles’ handling and stopping ability.
3. HIGH PRESSURE ALARM
The DORAN 360HD monitor is capable of monitoring for a High Pressure Warning. This
is a warning that is displayed when the baseline air pressure is exceeded by 25%. When
this happens the Green light will go out. The audible beeper will beep once per second
and HIGH PRESSURE will be displayed on the monitor screen. This can be caused by
extreme heat generated into the tire.
When the High-Pressure warning appears, STOP and check your tire(s) as soon
as safely possible, and check for the possible cause.
This can happen because of a dragging brake, bad wheel bearing, extreme temperature
conditions, or other mechanical failures that you might not detect. It is suggested that you
check the suspected tire position for a possible mechanical failure.
4. LOST SIGNAL ALARM
The DORAN 360HD monitor is capable of monitoring for
a lost sensor signal (see Figure 4-3). If the monitor is
unable to receive a signal from a sensor for more than 60
minutes an alarm will be displayed for that sensor. This
Fi
g
ure 4-3