SPECIFICATIONS
Main features
Overhead Concealed Mount or surface mount (push or pull)
Center pivot or offset hinges
Complete: doesn't require a power-boost module, nor a brake box
Hand is field reversible
Control inputs
Seven sensor inputs (individual LEDs indicate status):
o Trigger (radar, motion detector, push plate, access control, RF receiver…)
o Header (jamb) mounted presence sensor
o Door mounted, approach side presence sensoroDoor mounted, swing side presence sensor
o Safety beam presence sensor
o Fire (Smoke alarm)
o Breakout switch
Input for Program switch (Off/Auto/Hold Open)
All inputs, except for the Fire and Breakout inputs, are active low, compatible with:
o dry contact
o open collector
o TTL
o any signal up to 24 Vdc
Fire and Breakout inputs are active open.
Control outputs
Electric strike lock, open collector 100 mA max, 24 Vdc max. not protected. (requires additional relay,
not included; requires external supply, not included, for electric locks other than 24 Vdc)
Data (for dual zone sensors, such as BEA DK-12)
o Door closed: open circuit (0 Vdc)
o Door closing: 500 Hz square wave
o Door opening or open: 12 Vdc unregulated, 100 mA source max
Control inputs/outputs
Synch cable for side-by-side openers (part number DS2715-010)
o RXD TXD.
Power
Input: 115 Vac, 2 A Max
Output: 24 Vdc, 0.8 A, unregulated, short circuit protected, for sensors and accessories
Safety
Operates as a passive door closer in case of power failure or controller failure
Smoke alarm and breakout switch input
Misc
Operating air temperature -40 to 50 °C
Small size: 8" wide x 4 " tall x 2.5" deep
Microprocessor controlled, FLASH re-programmable, replaceable
Two controllers may be synchronized for side-by-side doors
Closed loop control