DORM
A
ED400 In Floor
Controller Manual
26
DORMA AUTOMATICS, Inc. 924 Sherwood Drive Toll-Free: 877-367-6211 DL3128-010
Lake Bluff, IL 60044 Fax: 877-423-7999 10/1/2007
E-mail: automatics@dorma-usa.com Subject to change without notice
OPERATION
Restore factory defaults
To reset the unit to the factory defaults, do the following:
o Turn the "Selector" knob to the "Misc Sel" position.
o Turn the "Dial" knob until "rSt" is shown in the display.
o Turn the "Selector" knob to the "Misc Adj" position. The display will show "nO".
Turn the "Dial" knob right. The display will show "yES" for just a split second, and thecontroller will restart.
Set-up without temporary stop
If for some reason you don't want stop the door at Electrical Back-Stopduring set-up, use this alternate procedure:
Manually open the door until it hits a mechanical stop (such as a wall or the operator'sinternal
Hard-Stop). Measure that opening angle exactly.
Turn on the controller
Indicate the type of door opener and the door mount.
Turn the "Selector" knob to the "Back-Stop" position. Use the Dial knob to change the Back-Stop
angle to the angle you just measured.
Turn the "Selector" knob to the "Learn" position.
Set the Program Switch in the "Auto" position.
The door will start opening slowly and hit the hard-stop.
As the door closes slowly to Latch-Stop, turn the "Selector" knob to the "Back-Stop" position. Use
the Dial knob to change the Back-Stop angle to the desired Electrical Back-Stop Angle (such as 90°).
Get out of the way!
The door will slam open to 45°, then close.
The display will show "CyC", meaningthat the opener needs a cycle learn.
The door will cycle open and closed at normal speed once.
Cycle testing
To cycle test the operator, do the following:
Apply AC power to the controller.
Set the Program Switch in the "Off" position.
Turn the "Selector" knob to the "Back-Stop" position. The display shows the programmed
Back-Stop angle in degrees.
Turn the "Dial" knob to adjust the programmed Back-Stop angle to the actual Back-Stop angle of
the door.
Turn the "Selector" knob to the "Learn" position. The display shows the Learn State. If it doesn't say
"ALL" (meaning it needs a complete learn), turn the"Dial" knob counter-clockwise until it does.
Set the Program Switch in the "Auto" position. The opener will start a learn:
o The door will open slowly to Back-Stop.
o The door will close slowly to Latch-Stop.
o The door may slam partially open, then close.
o The door will start cycling open and close, non stop.Note that the opener has limited obstacle
detection while learning: do not stop the door!
Turn the "Selector" knob to the "Mon Sel" position.
Turn the "Dial" knob until that "CyC" (for Number of Cycles) is shown in the display.
Turn the "Selector" knob to the " Monitor" position. The display will show the number of cycles. If
there are morethan 999 cycles, use the "Dial" knob to scroll the display.