DORM
ED400 In Floor
Controller Manual
24
DORMA AUTOMATICS, Inc. 924 Sherwood Drive Toll-Free: 877-367-6211 DL3128-010
Lake Bluff, IL 60044 Fax: 877-423-7999 10/1/2007
E-mail: automatics@dorma-usa.com Subject to change without notice
Pair of Doors
Two openers may be used to open two side-by-side doors. The doors may be synchronized or not. This operator is
not compatible with over-rebated doors.
Synchronized doors
The doors behave as if they are mechanically interconnected. In case of a presence at one door, both doors react
identically. In case of an obstacle at one door, the other door stops too, though a bit afterwards.
Wiring:
• Connect the grounds of the two controllers together
• Connect the motion sensor to both controllers, in parallel
• Connect each presence sensor from each door to both controllers, in parallel (but not the DATA line)
• Let each controller power its presence sensors (either controller can power the motionsensor)
• Connect a single Program Switch to both doors, in parallel
• Connect the RXD line of each controller to the TXD line of the other controller
• If you use the “Fire” input, connect the fire sensor to both controllers.
• If you use the “Break-out” input, connect the break-out switch to both controllers.
• Power the controllers from the same AC power source
FIRE
Fire
sensor
RXD
TXD
GND
Brk.O.
Break-out
switch
OFF
GND
H.O.
Mode
Switch
Motion
Sensor
+24V
TRIGGER
COM
+24V
HEADER
DATA
COM
+24V
SWING
COM
+24V
APPR.
COM
+24V
BEAM
COM
C
O
N
T
R
O
L
L
E
R
1
FIRE
RXD
TXD
GND
Brk.O.
OFF
GND
H.O.
+24V
TRIGGER
COM
+24V
HEADER
DATA
COM
+24V
SWING
COM
+24V
APPR.
COM
+24V
BEAM
COM
C
O
N
T
R
O
L
L
E
R
2
Header
Presence
Swing
Presence
Approach
Presence
Safety
Beam
Header
Presence
Swing
Presence
Approach
Presence
Safety
Beam