Pair of Doors
Two openers may be used to open two side-by-side doors. The doors may be synchronized or not. This operator is
not compatible with over-rebated doors.
Synchronized doors
The doors behave as if they are mechanically interconnected. In case of a presence at one door, both doors react
identically. In case of an obstacle at one door, the other door stops too, though a bit afterwards.
Wiring:
Connect the grounds of the two controllers together
Connect the motion sensor to both controllers, in parallel
Connect each presence sensor from each door to both controllers, in parallel (but not the DATA line)
Let each controller power its presence sensors (either controller can power the motionsensor)
Connect a single Program Switch to both doors, in parallel
Connect the RXD line of each controller to the TXD line of the other controller
If you use the “Fire” input, connect the fire sensor to both controllers.
If you use the “Break-out” input, connect the break-out switch to both controllers.
Power the controllers from the same AC power source
FIRE
Fire
sensor
RXD
TXD
GND
Brk.O.
Break-out
switch
OFF
GND
H.O.
Mode
Switch
Motion
Sensor
+24V
TRIGGER
COM
+24V
HEADER
DATA
COM
+24V
SWING
COM
+24V
APPR.
COM
+24V
BEAM
COM
C
O
N
T
R
O
L
L
E
R
1
FIRE
RXD
TXD
GND
Brk.O.
OFF
GND
H.O.
+24V
TRIGGER
COM
+24V
HEADER
DATA
COM
+24V
SWING
COM
+24V
APPR.
COM
+24V
BEAM
COM
C
O
N
T
R
O
L
L
E
R
2
Header
Presence
Swing
Presence
Approach
Presence
Safety
Beam
Header
Presence
Swing
Presence
Approach
Presence
Safety
Beam