Setup and Troubleshooting Instructions
Appendix B
Red LED status Display Description
Steady flashing
Control unit has detected error,
emergency mode activated.
On steady ln Hold-open device triggered.
Flashing times E Locking device error.
Flashing times E Safety sensor test error.
Flashing times E SVP PR DCW module test negative.
E Brake error
Flashing times
E
E
E
Incremental encoder error.
Flashing times E
Double door operation, nd system
has incompatible firmware version.
Flashing times E
Double door operation, nd system
has incompatible fire protection
setting.
Flashing times E
System error (test), second
shutdown option.
Flashing times E
System error (test), current
measuring circuit.
Flashing times E System error (test), braking circuit
Flashing times E EEPROM error
Flashing times E Motor overcurrent
Flashing times E Faulty learning cycle
B.. Red LED status codes.
B.. Error message memory.
. There are ten error message memory locations;
E through E .
. The latest error message is always stored in error
memory location E :
• As soon as another error occurs, the existing error
stored in E will be moved to E and the latest error
will be stored in E .
. A maximum of errors can be stored in memory
locations E through E.
. Identical error messages occurring one after another
are not stored again.
B. Red LED status codes