Pre-Installation Installation Training
A70622-D1
101/192
Different lens type
7000 series lasers head may be equipped with different lens
depending on the application.
The range of lens is given in the following table :
Note that spot size, energy density and marking fields varies
according to the lens type.
For instance :
1 - For a same range of laser head : if the focale distance increase, then the spot diameter
increase and the peak intensity decrease.
Peak Intensity (kW/cm
)
142,7
Peak Intensity (kW/cm
)
22,8
Peak Intensity (kW/cm
)
253,7
Peak Intensity (kW/cm
)
24,6
2- If Head range are differents, the spot diameter and the peak intensity are different for a same
lens.
Focal Length (mm) 300,0 Focal Length (mm) 300,0
Peak Intensity (kW/cm
)
15,9
Peak Intensity (kW/cm
)
63,4
Focal
distance
(mm)
Max.
Marking field
(mm)
75 50x50
100 70x70
150 105x105
175 120x120
200 140x140
225 155x155
250 175x175
300 210x210
360 250X250
400 280X280
482 340X340
600 415X415
720 500X500