After sales policy
General policy
This After Sales policy is released according to the 7031 HD and HD Quick scan launching.
Regular maintenance
The regular maintenance chart consists in changing filters, including 2 types:
1- Machine filters (air filters + pressurisation kit filter)
Replaced during preventive maintenance. MI recommends changing filters once a year.
2- Extractor filters (Pre-filter, main HEPA filter and Carbon gas filter)
Frequency of change: automatic management and led indicator to inform users.
Example of filter consumption for extractor ES500:
Values given in the table represent the filter replacement interval in months, for a 20-
characters message with 3mm character height.
Substrate
Filter Type
1 shift
3 shifts
1 shift
3 shifts
1 shift
3 shifts
Pre-filter
2
6
4
6
6
12
Combined filter
1
2
2
3
3
6
Pre-filter
2
3
3
6
6
12
Combined filter
1
2
2
3
3
6
Pre-filter
1
1
1
1
1
1
Combined filter
1
1
1
1
1
1
Pre-filter
1
1
1
1
1
1
Combined filter
1
1
1
1
1
1
Pre-filter
2
3
3
6
6
12
Combined filter
1
2
2
3
3
6
Pre-filter
3
4
4
6
6
12
Combined filter
1
2
2
3
3
6
PVC
Q filters per year
Inked paper
Glass
Painted metals
PET
150
500
680
White paper
below 150 products / min
150 - 500 products / min
500 + products / min
Notes:
- Longest combined filter life is 12 months, based on moisture absorption from the
atmosphere in addition to fume material accumulation.
- The combined filter must be changed at least once every 12 months.