J2 connector: I/O Signals
J2 Designation Default affectation Electrical features Comments
1
GND
EXTERNAL or INTERNAL
INPUTS
2
EXTERNAL
EMERGENCY
STOP
EXTERNAL EMERGENCY
STOP
3
INTERLOCK INTERLOCK
Should be linked to
+24VDC for normal
use
4
USER IN1 - -
5
USER IN2 - -
6
USER IN3 - -
7
USER IN4 - -
8
USER IN5 - -
9
USER IN6 - -
10
USER IN7 - -
11
USER IN8 - -
12 USER IN9
Reserved for pressure
switch (IP65 models)
Input mandatory on
IP65
13
USER IN10
Reserved for safety
(MANU mode)
ANODE OPTOCOUPLER
CATHODE LINKED TO GND
24VDC
-
14
+24VDC - -
15
+24VDC -
EXTERNAL or INTERNAL
-
OUTPUTS
16
USER OUT0 - -
17
USER OUT1 - -
18
USER OUT2 - -
19
USER OUT3 - -
20
USER OUT4 - -
21
USER OUT5 - -
22
USER OUT6 - -
23
USER OUT7 - -
24
USER OUT8 - -
25
USER OUT9 - -
26
USER OUT10 - -
27
USER OUT11 -
OPEN COLLECTOR NPN
EMETTER TO GND
24VDC
100mA fuse protected
-
28
USER OUT12 - -
29
- - -
30
USER OUT13 - -
31
- -
DRY CONTACT
24V 5A
-
32
GND -
EXTERNAL or INTERNAL
-