Pre-Installation Installation Training
A70622-D1
83/192
Calibrate power at installation
When installing a new laser, it is necessary to calibrate power, because all the sources do not
deliver exactly the same power.
Switch On the laser
Enter the username and password
User Name: “imaje”
Password: “0007ejami“
Place the power meter in front of the beam at
distance twice the focale distance
Press the red button of the power meter during
two seconds.
Press the button TEST LASER
After some seconds a warning Bip rings to stop
the measurement
Now, you have to adjust the power in “advanced
option setting” menu to obtain the nominal power
value
IMPORTANT: DO NOT PUT THE POWER METER AT THE FOCUS POINT YOU MAY DAMAGED
THE POWER METER.
Set the Laser test cycle to Continuous
Set the Laser test duty cycle to 100%
In the Head settings menu :
Set the Power adjustment at 100%
Out of the focale