1.7 - M
ECHANICAL
ADJUSTMENTS
Installation Guide DeltaWave
C
HAPTER
1
17
1.7.3 C
HIPWAVE
SETTING
1. When the mainwave and the backplate are adjusted set the chipwave. Place the glassplate
(partnr. 627.3785) above the chipwave.
F
IGURE
1.19 G
LASSPLATE
ON
C
HIPWAVE
2. Adjust the pumpspeed such that the wave touches the glassplate over the full width in an
unbroken line off about 10 mm. If the line is too narrow at one end use the screws in front
and/or rearside of the chipnozzle to correct.
F
IGURE
1.20 C
ORRECTING
CHIPWAVE