Installation Guide DeltaWave
C
HAPTER
1
21
6. Set the pump-frequency and start/stop position in the PC program.
7. Test options: move once to check if the nozzle move and spray correctly.
8. Place the glassplate (or an empty PCB) in the conveyor to check if the underside is wetted
well with flux.
9. If necessary correct the pump-frequency or the pitch and control again.
1.7.8 D
ENSITY
CONTROL
UNIT
1. Fill the diluent-supply container or place the vessel of the supplier in the machine.
2. Place the suctionpipe on the vessel/container.
Be sure that the fluxer is installed correctly.
3. Switch on the density unit on the PC.
4. Check after 5 minutes the fluxdensity on the pc screen. If this measured value deviate to
much from the real value calibrate the density unit.