1.7 - M
ECHANICAL
ADJUSTMENTS
Installation Guide DeltaWave
C
HAPTER
1
19
1.7.6 S
PRAY
DRUMFLUXER
1. Check if the fluxer is level. If necessary correct the threaded ends.
2. Check if the drain is closed.
3. Fill the fluxer up to the top of the overflow pipe with flux of the desired density.
4. Fill the fluxsupply container or place the vessel of the fluxsupplier in the machine.
5. Place the suctionpipe on the vessel/container.
6. Switch on the fluxer.
7. Check that the air supply is on with a pressure of max. bar.
8. The angle of the spray pipe inside the drum is 90ø with respect to the transport-system.
9. Adjust the pressure with the regulator on the pneumatic panel in frontside of the machine.
10. When not spraying a minimum airflow should pass the spraypipe to prevent it from clogging.
This flow can be corrected inside the pneumatic panel.
11. Place the glassplate (or an empty PCB) in the conveyor to check if the underside is wetted
well with flux.
12. If necessary correct the pressure and control again.