EasyManua.ls Logo

Dover Vitronics Soltec DeltaWave 6622cc - Page 32

Dover Vitronics Soltec DeltaWave 6622cc
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DESCRIPTION UNITS
Input Voltage V
3x400 or 3x415
Power Minimum
kVA 34
Power Maximum
kVA 50
I largest Load
A 80
Weight Machine with solderpot filled
kg / lb 2450 / 5400
Shipping Weight with solderpot filled
kg / lb 2650 / 5840
Carrying capacity floor per leveling feet kg / lb 450 / 992
Nitrogen Requirements bar / psi 6 / 87
Air Requirements bar / psi 6 / 87
Nitrogen Consumption
m
3
/h / CFH
15 / 530
Air Consumption
m
3
/h / CFH
30 / 1060
Exhaust Requirements Exhaust 1 with sprayfluxer
m
3
/h / CFH / Pa
1000 / 35320 / 800
Exhaust Requirements Exhaust 1 with foamfluxer
m
3
/h / CFH / Pa
250 / 8830 / 150
Exhaust Requirements Exhaust 2
m
3
/h / CFH / Pa
600 / 21192 / 250
Clearance for opererate & maintenance FRONTSIDE cm / inch 100 / 39.37
Clearance for opererate & maintenance BACKSIDE cm / inch 150 / 59.05
Clearance for opererate & maintenance LEFTSIDE cm / inch 75 / 29.52
Clearance for opererate & maintenance RIGHTSIDE cm / inch 75 / 29.52
Installation sheet DeltaWave 6622cc