Instructions for use
BiliLux
WARNING
To properly use this medical device,
read and comply with these
instructions for use.
LED phototherapy light
Software 1.n

Table of Contents

Other manuals for Dräger BiliLux

Questions and Answers

  • R
    Richard MasonAug 1, 2025
    Why is the irradiance too low on my Dräger Medical Equipment?
    • S
      sarah09Aug 1, 2025
      Low irradiance in Dräger Medical Equipment can occur for several reasons: * The light may be too far from the patient; adjust the height of the light. * The irradiance setting may be too low; increase the irradiance setting. * The LEDs may be at the end of their useful life; replace the LED panel. * There might be a radiometer reading error; correct the sensor position and retry the reading.
  • D
    David BurkeAug 6, 2025
    What to do if the message ERR is displayed on the radiometer screen of my Dräger Medical Equipment?
    • C
      Christopher JacksonAug 6, 2025
      If the message ERR appears on the radiometer screen of your Dräger device, it indicates that the value is out of range. Try positioning the radiometer closer to the patient and attempt the reading again. This message can also appear if the radiometer is too close to the LEDs, so attempt the reading again. If the message persists, it could indicate a faulty radiometer.
  • B
    Brandon HatfieldAug 9, 2025
    How to fix Dräger BiliLux if LED lights do not illuminate?
    • C
      cartermaryAug 9, 2025
      If the LED lights on your Dräger Medical Equipment do not illuminate, the cause may be a loose power cable connection. Ensure the power cable is securely connected to both the phototherapy light and the mains power. If the issue persists, the LED panel may need replacement. When replacing parts, use only Dräger spare parts.
  • M
    Michael DunnAug 14, 2025
    What to do if my Dräger BiliLux Medical Equipment displays a USB error on the phototherapy report screen?
    • R
      richardsonruthAug 14, 2025
      The 'USB error' message on the phototherapy report screen of your Dräger device indicates that you tried to export a phototherapy report without a USB flash drive connected. To resolve this, connect a USB flash drive to the phototherapy light and attempt the export again.
  • J
    Jodi GonzalezAug 18, 2025
    What to do if Dräger Medical Equipment displays 'No export during running therapy'?
    • E
      Emily HendersonAug 18, 2025
      The message 'No export during running therapy' on your Dräger device means that you attempted to export a phototherapy report while the therapy was active. To resolve this, stop the therapy by pressing the Reset button on the phototherapy screen, and then try the export again.
  • G
    gibbsnatalieAug 22, 2025
    How to fix a Dräger BiliLux Medical Equipment trolley that does not maintain set height?
    • H
      hensonstephanieAug 22, 2025
      If the trolley of your Dräger Medical Equipment does not maintain its set height, it is likely that the tightening knob on the trolley is not tightened sufficiently. Tighten the knob until it is secure.
  • A
    Andrea BuckAug 27, 2025
    How to fix a Dräger Medical Equipment spring arm that does not maintain set position?
    • M
      melissa99Aug 27, 2025
      If the spring arm of your Dräger Medical Equipment does not maintain its set position, the joints of the spring arm may be loose. Tighten the joints on the spring arm.

Summary

Safety-related Information

Target Groups and Responsibilities

Defines user, reprocessing, and service personnel roles and requirements for safe operation.

Basic Safety Instructions

Provides fundamental safety guidelines for device operation, maintenance, and user restrictions.

Electrical and EMC Safety

Covers precautions for electrical connections, grounding, and electromagnetic compatibility.

Explosion, Fire, and Drug Storage Safety

Outlines safety measures to prevent explosion, fire hazards, and proper drug storage.

Mechanical Safety and Device Failure

Addresses mechanical safety aspects of the device, trolley, and actions for device failure.

Application

Intended Use

Specifies the purpose and target patients for the BiliLux phototherapy light.

Indications and Contraindications

Lists conditions for which the BiliLux is indicated and contraindications.

Overview

BiliLux Phototherapy Light Components

Describes the BiliLux light, its top, bottom, and rear views, and control panel.

BiliLux with Optional Spring Arm and Trolley

Details configurations of the BiliLux with optional spring arm and trolley.

Radiometer and Symbols

Explains the optional radiometer and key symbols used in the manual.

Operating Concept

Control Panel Overview

Describes the buttons and LED indicators on the BiliLux control panel.

Displaying BiliLux Screens

Explains how to navigate and view different screens on the device.

Adjusting the BiliLux with Spring Arm

Guides on how to adjust the position of the BiliLux with a spring arm.

Assembly and Preparation

Proper Assembly and Functional Checks

Guides on assembling the device and performing functional checks.

Installing with Spring Arm

Details the installation of the BiliLux with an optional spring arm.

Installing with Trolley

Provides steps for assembling the BiliLux with an optional trolley.

Getting Started

System Startup

Details the procedure for powering on and starting the BiliLux device.

Functional Check Procedure

Outlines the steps for performing a functional check of the device.

Operation

Positioning the BiliLux

Covers proper positioning of the device for safe operation near incubators/warmers.

Adjusting Light and Starting Therapy

Guides on adjusting light distance, coverage, and starting therapy.

Using the Radiometer and Exporting Reports

Explains radiometer use for irradiance measurement and exporting therapy reports.

Ending Therapy and Shutting Down

Provides instructions on ending therapy and safely shutting down the device.

Configuration

Adjusting Date and Time

Guides on setting the device's date and time.

Adjusting Language

Explains how to change the device's display language.

Troubleshooting

Fault, Cause, and Remedy

Lists common faults, their causes, and remedies for troubleshooting the device.

Reprocessing

Reprocessing Safety Information

Covers safety warnings related to reprocessing and infection risks.

Reprocessing Procedures and Disinfectants

Outlines validated reprocessing procedures and suitable disinfectants.

Service

Service Safety Information

Covers safety warnings for performing service on the device.

Inspection and Safety Checks

Details inspection intervals and safety checks for device maintenance.

Maintenance Procedures

Lists preventive maintenance intervals and instructions for components.

Disposal

EU Directive 2002;96;EC Disposal

Provides disposal information according to EU WEEE directive.

Technical Data

Device Classification and Physical Attributes

Details device classification and lists physical attributes like dimensions and weights.

Environmental and Electrical Requirements

Specifies operating conditions, power requirements, and electrical specifications.

Irradiance and Distribution

Presents irradiance values, spectral distribution, and distribution data.

EMC Declaration and Immunity

Details EMC declaration, emissions, and immunity specifications.

List of Accessories

Device

Lists the main BiliLux LED phototherapy system.

Accessories

Lists available accessories such as phototherapy masks.

Optional Components

Lists optional components like radiometer, trolley, and spring arm.

Dräger BiliLux Specifications

General IconGeneral
ApplicationTreatment of neonatal jaundice
Light SourceLED
Safety StandardsIEC 60601-1, IEC 60601-2-50
TypePhototherapy device
IrradianceUp to 30 µW/cm²/nm
Power Supply100-240 V AC, 50/60 Hz
Service Life20, 000 hours