EasyManuals Logo

Dräger Polytron FX User Manual

Dräger Polytron FX
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
19
6.4 Physical Specifications
6.4.1 Aluminum Version
Enclosure ......................................................................................... NEMA 4X (IP66)
Size ............... L x W x D approx., FX PR 6.5” x 4.5” x 4”; (165 x 115 x 100mm)
FX LC 7.2” x 4.5” x 4”; (185 x 115 x 100mm)
FX IR 11.5” x 4.5” x 4”; (295 x 115 x 100mm)
Weight approx. ..................................................... FX PR, FX LC 3.3 lbs. (1.5 kg)
FX IR 4.2 lbs. (1.9 kg)
6.4.2 Stainless Steel Version
Enclosure ......................................................................................... NEMA 4X (IP66)
Size ........... L x W x D approx., FX PR 6.6” x 5.1” x 4.7”; (170 x 130 x 120mm)
FX IR 11.6” x 5.1” x 4.7”; (295 x 130 x 120mm)
Weight approx. .................................................................... FX PR 7.1 lbs. (3.2 kg)
FX IR 8.0 lbs. (3.6 kg)
6.5 Environmental Parameters
Temperature ............................. FX PR, FX LC –40 to 175 °F, (–40 to 80 °C)
FX IR –40 to 150 °F, (–40 to 65 °C)
Pressure ............................................. 20.7 to 38.4 in. of Hg (700 to 1300 mbar)
Humidity .................................................................... 5 to 95% RH, non-condensing
Maximum Air Velocity ............................................................. 19.5 ft/s ( 6 m/s)
6.6 Ambient Influences
See sensor data sheets.
Physical Specifications
Environmental Parameter
Ambient Influences