EasyManua.ls Logo

Dräger X-zone 5000

Dräger X-zone 5000
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Technical Data
Frequency ranges:
Dimensions: approx. 490 x 300 x 300 mm
(H x W D)
Weight:
with battery, 12 Ah
with battery, 24 Ah
approx. 7 kg
approx. 10 kg
Ambient conditions:
During operation
During storage
-2C to +5C
-2C to +7C
700 to 1300 hPa
max. 95% relative humidity
Alarms:
Visual, 360° LED green life signal;
red life signal;
green/red subsidiary alarm
Audible, 360° 108 dB (A) at 1 m distance
120 dB (A) at 30 cm distance
Battery:
Operating time, 12 Ah
(
20 °C)
60 Hours at 15 minute alarm
per day and ‚
fully equipped
Dräger X-am 5x00
Operating time, 24 Ah
(
20 °C)
120 hours
Charging time, 12 Ah < 6 hours
Charging time, 24 Ah < 10 hours
Pump: up to 30 m hose
0.5 l/min
Networking of
devices:
Only service department
can switch the frequency
429/433/868/915 MHz
with a typical range of 100 m in
industrial surroundings
(environmental factors may
affect the range).
Automatic establishment of
wireless connection.
Up to 25 devices can be
connected on a wireless
network.
Combined wireless/cable
operation possible.
Relay output:
Max. voltage (U
i
):
Max. switching current
(I
i
):
Max. continuous
current:
Max. switching capacity
(P
i
):
For ohmic loads only:
Reactances
No connection with:
20 V
0.25 A
0.25 A
3W
C
i
100 pF; L
i
10 µH
Capacitive or inductive
loads
Approvals:
ATEX: I M1 Ex ia I Ma
II 1G Ex ia IIC T3 Ga
IECEx: Ex ia I Ma
Ex ia IIC T3 Gb
Detection range: see the Technical Manual for
Dräger X-am 5x00
Country, region Frequency range (MHz)
EU, Switzerland, Norway,
Turkey
868
South Africa 868
USA/Canada 915
Singapore 868
Australia 915
India 915
Japan 429
Russia 433
DRAFT 02 - 08/02/10