Section 5: Programming
5/6 Keypad Panic Alarm-[P] Key Alarm/Restore
Sent when [P] Key alarms/restores occur.
7/8 Auxiliary Input Alarm/ Restore
Sent when an alarm condition occurs/ is restored on PGM 2 (if configured as an input).
[021] Fire Alarms 1
3/4 PGM 2 2-Wire Alarm/Restore
When PGM 2 is programmed as a 2-wire smoke alarm, this reporting code is sent when an alarm condition is detected and
when it is restored.
[101] Tamper Events
3/4 Module Tamper/Restore
This reporting code is transmitted when a system module enters a tamper alarm state and uses the System Tamper Alarm
and Tamper Restore call direction.
5 Keypad Lockout
Sent when a number of invalid access codes have been entered at a system keypad.
This reporting code is sent to the system Tamper Alarm & Tamper Restore call direction group.
7 Remote Lockout
Sent when a number of invalid access codes have been entered through DLS or Integration. This reporting code is sent to
the system Tamper Alarm & Tamper Restore call direction group.
[201] Open/Close Events 1
1/2 User Closing/Opening
This reporting code is transmitted when a user arms/disarms a partition and uses the Opening and Closing call direction.
5/6 Special Closing/Opening
This reporting code is transmitted when a partition is closed/opened using quick arm ([*][0]), downloading, or Stay or Away
function keys without an access code. The Opening and Closing call direction group is used for this reporting code.
7/8 Keyswitch Opening/Closing
This reporting code is transmitted when a keyswitch zone is used to arm or disarm the system.
[202] Open/Close Events 2
1 Automatic Closing
This reporting code is transmitted when a partition is automatically armed or schedule armed and uses the Opening call dir-
ection group.
2 Automatic Disarm
This reporting code is transmitted when a partition is automatically disarmed when a scheduled time of day is reached.
3 Auto Arm Cancellation/Postpone
This reporting code is transmitted when the automatic arm sequence is canceled during a pre-alert and uses the Opening
and Closing call direction group.
[211] Miscellaneous Open/Close Events
1/2 Late to Close/Open
This reporting code is transmitted when a partition is not disarmed before the automatic disarm time, when the late to open
option, ([*][6], option 9) is enabled. The Opening and Closing call direction group is used for this reporting code.
5 Exit Fault
This reporting code is transmitted when an exit error occurs and entry delay expires before the system is disarmed. The
Alarms and Restores call direction group is used for this reporting code.
If the delay zone that caused the exit error has cross zoning enabled, the exit fault and zone alarm transmits if a second zone
is not tripped. The local alarm sequence follows cross zoning rules. The exit error is transmitted with the zone alarm that
caused the fault, even if that zone has transmission delay enabled.
- 102 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals