Appendix 4: Regulatory Approvals
Note: For ULC Residential Fire installations, minimum bell time-out is 5 min. For UL Home Health Care installations, minimum bell time-out is 5 min. For UL Com-
mercial Burglary installations, minimum bell time-out is 15 min.
l Temporal Three Fire Signal shall be enabled (section [013], opt.8 ON)
l Arm/Disarm Bell Squawk shall be enabled when using wireless key PG4939/PG4929/PG4949 (section [014], option 1 shall be ON)
l A code shall be required for bypassing (section [023], option 4 shall be ON)
l Trouble beeps shall be enabled (section [022], option 7 shall be ON)
l AC trouble indication LED shall be enabled (Keypad Programming, section [022], options 5 and 6 shall be ON)
l DACT Communicator shall be enabled for Supervising Station Monitoring (section [380], option 1 shall be ON)
Note: The DACT communicator for this product has no line security.
l Telephone Line Monitoring (TLM) shall be enabled (section [015], option 7 shall be ON)
Note: This product is programmed to perform 5 (min.) to 10 (max.) attempts for communication of an event to the supervising station. If unsuccessful, a Fail To Com-
municate (FTC) trouble is generated.
l Test transmission cycle shall be set for monthly transmission (refer to section [351])
Note: For ULC Residential/Commercial installations set for daily test transmission.
l Wireless Supervision window shall be set to 4 hours for Fire Installations (Wireless Programming, section [804]>[802] shall be programmed with the value
16)
l Wireless Supervision window shall be set to 4 hours for Burglary Installations only (Wireless Programming, section [804]>[802] shall be programmed with the
value 96)
l RF Jam detection shall be enabled (refer to Wireless Programming (section [804][801], option 00 shall be OFF)
l New Alarms will Disconnect 2-way Audio (section [022], option 6 OFF)
UL Central Station and Police Connect with Standard or Encrypted Line Security Service
l The installation must use the Models TL2803G(R) IP/3G Interface, 3G2080(R) 3G Interface or TL280(R) IP Interface, which communicates over Cellular
Data Network or an Ethernet network 10/100BaseT to the compatible Sur-Gard System I/II/III/IV receiver
l Polling time shall be 200 seconds and compromise detection time shall be 6 min.
l For Encrypted line security applications, the Models TL2803G(R) IP/3G Interface, 3G2080(R) 3G Interface or TL280(R) IP Interface shall have the Encryp-
tion Key enabled (AES128 bit encryption algorithm is validated under NIST Certificate No.2645
l Wireless Supervision window shall be enabled (refer to Wireless Programming, sections [804]>[802])
UL Local, Central Station and Police Connect with No Line Security Service
l The installation shall use a Bell UL Listed for Mercantile local alarms (e.g., Amseco Model MBL10B bell with Model AB-12 bell housing). Connections from
the control unit to the bell shall be made in conduit. (Optional for central Station)
l The bell timeout shall be programmed for 15 minutes minimum
l At least one system remote keypad with tamper switch shall be employed
l The integral DACT shall be enabled and shall be programmed to provide a low battery transmission
l The control panel shall be in a separately listed CMC-1 or PC4050CA attack resistant enclosure
l The maximum entry delay time shall not exceed 45s as a result of the attack test. The maximum exit delay time shall not exceed 60 s.
l A tamper switch shall be used to protect the enclosure cover of the control unit. A tamper switch shall also be used on the keypad rear to detect removal from
the wall
l 24 h check in transmission shall be enabled
l Open/Closing acknowledgement enabled.(Not Police Station)
l The Installation shall use the internal dialer (DACT) alone or in conjunction with Models TL2803G(R) IP/3G Interface, 3G2080(R) 3G Interface or TL280(R) IP
Interface, which communicates over Cellular Data Network or an Ethernet network 10/100BaseT to the compatible Sur-Gard System I/II/III/IV receiver
UL Home Health Care Signaling Equipment
l There must be at least two keypads, one of either one of the compatible keypads models HS2LED, HS2LCD(P), HS2ICN(P), HS2LCDRF(P)9, HS2ICNRF
(P)9 and HS2TCHP
l Each system shall be programmed to activate an audible Trouble signal within 90 seconds upon loss of microprocessor memory
l The HS2TCHP shall be used along with another compatible model keypad in order to provide audible supervision for homehealth care or medical install-
ations.
ULC Central Station Fire and Burglary Monitoring Installations
l For installation requirements, levels of security, communication modules and configurations (Refer to the ULC Installation Information Sheet, DSC
#29002157)
l Use a CSA/cUL approved transformer (hardwired connections required for Fire Monitoring)
l All tamper circuits may be connected to the same zone
l HS2TCHP touch screen keypad is for supplementary use only with ULC Commercial Fire Monitoring
Programming
The notes in the programming sections of the PowerSeries Neo Reference Manual describing the system configurations for UL/ULC listed installations shall be imple-
mented.
Control of the Protected Premises
In order to have a UL certificated system, the protected area shall be under the responsibility of one ownership and management (i.e., one business under one name).
This may be a group of buildings attached or unattached with different addresses but under the responsibility of someone having mutual interest. The person of mutual
interest is not the alarm-installing company.
Note: This does not apply to strip mall applications where each independent business must have their own separate alarm system.
e.g.,1: A commercial partitioned system that has an office and a warehouse area in a building where each area can be armed or disarmed independently. e.g.,2: A res-
idential system partitioned so that the garage area is armed separately from the house.
- 206 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals