EasyManuals Logo

DSC HS2016 Reference Manual

DSC HS2016
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
Section 5: Programming
149 Alternate Communicator
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 Fire Alarm
ON: activates with fire alarm, [F] key, fire zones, 2-wire smoke.
OFF: does not activate with fire alarm.
05 Panic Alarm
ON: activates with panic alarm, [P] key, panic zones.
OFF: does not activate with panic alarm.
06 Burglary Alarm
ON: activates with burglary alarm.
OFF: does not activate with burglary alarm.
07 Open/Close
ON: activates with opening or closing.
OFF: does not activate with opening or closing.
08 Zone Auto-Bypass
ON: activates when a zone is automatically bypassed.
OFF: does not activate when a zone is automatically bypassed.
09 Medical Alarm
ON: activates with medical alarm, [+] key, medical zones.
OFF: does not activate with medical alarm.
10 Burglary Verified
ON: activates with burglary verified alarm (or police code).
OFF: does not activate with burglary verified alarm.
11 Open After Alarm
ON: activates when the system is disarmed with an alarm in memory.
OFF: does not activate when the system is disarmed with an alarm in memory.
12 Emergency Alarm
ON: activates with zone emergency alarm.
OFF: does not activate with zone emergency alarm.
13 Duress Alarm
ON: activates with duress alarm.
OFF: does not activate with duress alarm.
14 Hold Up verified
ON: activates when a verified holdup event is detected.
OFF: does not activate when a verified holdup event is detected.
155 System Trouble
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
- 80 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals