Section 5: Programming
7 Trouble Beeps are Silent
ON: When a trouble is detected on the system, trouble beeps are not sounded at the keypad with the exception of Fire
troubles.
OFF: When a trouble is detected on the system, trouble beeps are sounded at the keypad.
Note: This option must be OFF for UL Residential Fire applications.
8 Keyswitch Arms in Away Mode
ON: Keyswitch arming arms the alarm system in away mode.
OFF: Keyswitches only arm the system in away mode if an entry/exit zone is violated during exit delay.
Note : Proximity tag arming follows this section.
[023] System Option 11
1 Ready LED Flashes for Force Arm
ON: If a force arm capable zone is tripped, partition keypads flash the ready LED in the disarmed state instead of illuminating
it steadily. If a non-force arm capable zone is tripped, the ready LED turns off.
OFF: If a force arm capable zone is tripped, the Ready LED is illuminated steadily. If a non-force arm capable zone is tripped,
the Ready LED turns off.
2 Not Used
3 Tamper/Fault Detection
ON: The following trouble conditions, when configured to generate audible alarm conditions, will contribute to a burglary veri-
fication sequence when sequential detection is used. When enabled, a bell circuit trouble will also generate an audible
alarm condition using other sirens that assigned to the partition.
l TLM trouble
l Bell circuit trouble
l Zone fault
l Module supervisory trouble
l Alternate Communicator fault
l Ethernet Trouble
OFF: Trouble conditions are displayed and processed as standard operation.
Note: This option applies to the Sequential Detection feature only.
4 Access Code Required for [*][1]
ON: When using the [*][1] Bypass Zones command, an access code must be input before zones are bypassed.
OFF: An access code is not required to bypass zones using [*][1].
5 Access Code Required for [*][2]
ON: When using the [*][2] View Troubles command, an access code must be input before system troubles can be viewed.
OFF: An access code is not required to view troubles using [*][2].
6 Access Code Required for [*][3]
ON: When using the [*][3] View Alarms in Memory command, an access code must be input before the alarm memory can be
viewed.
OFF: An access code is not required to view alarms in memory using [*][3].
7 Access Code Required for [*][4]
ON: When using the [*][4] Chimes command, an access code must be input before chimes can be toggled on and off.
OFF: An access code is not required to toggle chimes using [*][4].
8 [*][6] Accessibility
ON: All user codes provide access to the [*][6] menu.
OFF: Only the master code provides access to the [*][6] menu.
[024] System Option 12
1 50Hz AC/60Hz AC
ON: Incoming AC power cycles at 50Hz.
- 95 -