EasyManuals Logo
Home>DSC>Control Panel>LCD5500Z

DSC LCD5500Z User Manual

DSC LCD5500Z
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
System Introduction
S E C T I O N 1
1.1 Specifications
Control Panel Specifications
Flexible Zone Configuration:
8 Fully Programmable Zones
38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance
Expandable to 32 Zones
Keypads with zone inputs available (PC/KP5508Z, PC/KP5516Z, PC/KP5532Z, LCD/KPL5500Z)
Hardwired expansion available using the PC5108 Eight Zone Expansion module, the PC5700 Fire
module, or the PC5720 Fire and DVACS module.
Wireless expansion available using the PC5132 Wireless Zone Expansion module (up to 32 wireless
zones, 900MHz, True Spread Spectrum Technology, Fully Supervised)
Normally Closed, Single EOL, or Double EOL zone supervision
2-Wire Smoke Input (via PGM2 input)
27 Zone Types, 8 Programmable Zone Options
2 Partitions
Audible Alarm Output:
Supervised Bell Output (current limited at 3 amps), 12 V
DC
Steady or Pulsed Output
EEPROM Memory:
Will not lose programming or system status on complete AC and Battery failure
Programmable Outputs:
Up to 14 Programmable Voltage Outputs, 23 programmable options
One High Current (300 mA) PGM output with 2 wire smoke detector capability on main panel
Maximum Loop Current is 1.5 mA when the 2-wire smoke detector configuration is used
One Low Current (50 mA) PGM output on main panel
Eight Additional Low Current (50 mA) PGM outputs available using the PC5208 module
Four High Current (1 Amp) PGM outputs Available Using the PC5204 module
1 PC5204 Output Fully Supervised for Siren Output
Powerful 1.5 Amp Regulated Power Supply:
500 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components replace fuses
Supervision for loss of AC Power, Low Battery
Internal Clock Locked to AC Power Frequency
Power Requirements:
Transformer = 16.5 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid
Remote Keypad Specifications:
8 Different Keypads Available:
- PC5508(Z)/KP5508(Z) 8 Zone LED Keypad - PC5532(Z)/KP5532(Z) 32 Zone LED Keypad
- PC5516(Z)/KP5516(Z) 16 Zone LED Keypad - LCD5500(Z)/KPL5500(Z) Alphanumeric Keypad
Each Keypad has 5 Fully Programmable Function Keys Connect up to 8 Keypads
Four Wire (Quad) Connection to Keybus Built in Piezoelectric Buzzer
Digital Communicator Specifications:
Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging
3 Programmable Phone Numbers 2 Account numbers
Supports LINKS1000 Cellular Communication DTMF and Pulse Dialing
DPDT Line Seizure Anti-jam Feature
Split Reporting of Selected Transmissions to Each Telephone Number
System Supervision Features
The PC5010 continuously monitors a number of possible trouble conditions including:
AC Power Failure Trouble by Zone Fire Trouble
Telephone Line Trouble Low Battery Condition Bell Output Trouble
Loss of Internal Clock AUX Power Supply Fault Tamper by Zone
Failure to Communicate Module Fault (Supervisory or Tamper)

Table of Contents

Other manuals for DSC LCD5500Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC LCD5500Z and is the answer not in the manual?

DSC LCD5500Z Specifications

General IconGeneral
BrandDSC
ModelLCD5500Z
CategoryControl Panel
LanguageEnglish

Related product manuals