22
Arm Interior (12)
This function key provides the user with a simple method
for adding Stay/Away zones back into the system.
Command Output X (X=1-8) (13-20)
This function key provides the user with a simple method
for activating a PGM Output programmed as Command
Output option #1-8 (see 11.3 ‘Programmable Output
Options‘). Once this key is pressed, the user may need to
enter a valid access code if the Cmd.Out X Rq Cd
Cmd.Out X Rq Cd Cmd.Out X Rq Cd
Cmd.Out X Rq Cd option is
enabled for the command output.
Silence Trouble (21)*
Pressing this key silences trouble beeps for the partition. If
the Trouble Requires Code system toggle option is enabled,
the user will be required to enter an access code in order for
this function key to work (see 7.9 ‘Access Code Options‘).
Silence Bells (22)*
Pressing this key followed by entry of a valid access code
will silence the partition’s fire alarms.
Fire Reset (23)*
Pressing this key followed by entry of a valid access code
will restore all fire alarms.
Fire Drill (24)
Pressing this key followed by entry of a valid access or Mas-
ter code will initiate the Fire Drill. This is the equivalent of
entering [][6][Access/Master Code][5].
Lamp Test (25)
Pressing this key followed by entry of a valid access or Mas-
ter code will initiate the Lamp Test. This is the equivalent of
entering [][6][Access/Master Code][8] (see
Instruction
Manual
, section 5.3 ’Lamp Test’).
Fire Insp Tst (26)
Pressing this key followed by the Walk Test Code will ini-
tiate the Fire Inspector’s Test Mode. This is the equivalent of
entering [][6][Walk Test Code][4]. If the test mode is
already active, pressing this key followed by the Walk Test
Code will disable the test ([][6][Walk Test Code][5]).
User Help (27)
Pressing this key will automatically create a connection
between the keypad and the Escort4580. The Escort starts
prompting immediately through the Audio Station
assigned to the keypad.
The Escort4580 v1.3 must be enrolled and programmed for
this to work. Make sure that this function key is
not
pro-
grammed to require an access code entry (seeFunction
Key Options‘).
The intercom station must be programmed as ‘intercom’.
Quick Bypass (28)
Pressing this key, followed by entry of an access code, will
bypass all zones on the partition programmed as Quick
Bypass for the length of the Quick Bypass Duration. Press
this function key again during the Quick Bypass Pre-alert to
restart the countdown.
This is the same as entering [][6][Access/Master
code][14]. See ‘24Hr Quick Bypass (24)‘.
Music Input (29)
Pressing this key will turn on the background music (if pro-
grammed) on all the audio stations which hear general
pages.
NOTE: The Monitor and Music Input cannot be on at the
same time. If they are both enabled, the Monitor will take
priority and the Music will not be heard.
Temporary Code (30)
Pressing this function key, followed by an access code, will
enable/disable temporary codes on the partition assigned
to the keypad. The keypad will sound 3 short beeps when
temporary codes are enabled on the partition and one long
beep when temporary codes are disabled on the partition.
The ’T-code’ LED on the LCD45XX will be on when tempo-
rary codes are active, and off when they are not active. See
section 7.3 ‘Programming Access Codes‘.
Cancel Key (31)
Pressing this key when the partition is NOT in alarm will:
Silence troubles (if in normal mode)
Exit from the current menu
When a user presses this key when the partition is in alarm
the panel will:
1. Request a valid access code.
2. Transmit a Cancel code to the central station.
3. Sound 3 beeps on the keypad, display "Alarm Can-
celed" on the keypad and sound a voice message
stating "Alarm Canceled".
NOTE: For this feature to work, make sure that the Alarm
Cancel reporting code is programmed (see Appendix B:
‘Reporting Codes‘).
NOTE: Alarm Cancel does not initiate listen-in.
Zone Control (32)
Pressing this key will cause the programmed zone to be
violated. One of zones 121-128 can be assigned to any func-
tion key. Do not assign more than one function key to the
same zone. Do not use zones assigned to zone control keys
for any other purpose.
The panel will follow the same procedure as when the zone
is normally violated. The zone will then automatically
restore. Zones assigned to zone control keys will not be
supervised.
NOTE: Do not assign fire zones (zone types 07-11) to this
function key.
Arm All (33)
Attempts to arm all partitions assigned to a specific user in
Away mode. If the function key is programmed to not
require a code, then the panel will attempt to arm all active
partitions. If a partition is not ready to arm, the message
’Unable to arm all partitions’ will appear and none of the
partitions will be armed. This function key option is only
available to system keypads. If code is required then the
panel attempts to arm all partitions to which the code is
assigned.
* Not to be used with UL Listed systems