37
If all Seismic Sensor zones have properly gone into
alarm and restored, the ready light will be activated and
no fault will be initiated.
If any of the Seismic Sensor zones fail to go into alarm or
to restore a "Zone Fault" event will be transmitted and
the event number will be logged to the event buffer, for
each zone that failed.
If the Force Arming bit has been set for all Seismic Sen-
sors that have failed, the partition shall allow arming
fol-lowing the normal force arming procedure.
If the Force Arming bit has not been set for all Seismic
Sensors that have failed, the ready light will be deacti-
vated (if active), an error tone will sound, and the corre-
sponding zone will indicate as "Open" in the menu.
Global seismic zones will not be supported.
If a Seismic zone fails the Seismic Sensor test the zone
will indicate, as "Open" and the partition will be unable
to arm. (Unless the force arm bit is enabled).
The panel will show the zone as open and a trouble will
be displayed in * 2 menu called 'Seismic Trouble'
The trouble can only be cleared by entering\exiting
installer's mode.
11.4 Output Pulse Times
Ref #: [000706XX] where XX = pulse time type 00-03
This section will allow you to select the amount of time the
PGM output will remain active after being triggered. Valid
entries are from 000 to 255 seconds. The available pulse
times are listed below:
Kissoff Pulse (00)
Any output programmed for ’Kissoff’ can be active from 000
to 255 seconds. The default setting is 003 seconds.
Ground Start (01)
Any output programmed for ’Ground Start’ can be active
from 000 to 255 seconds. The default setting is 000 seconds.
NOTE: The panel will wait until the end of the Ground Start
before dialing. This feature must not be used on UL listed
systems.
Chime Pulse (02)
Any output programmed for ’Chime Pulse’ can be active
from 000 to 255 seconds. The default setting is 002 seconds.
Duress Pulse (03)
Any output programmed for ’Duress Pulse’ can be active
from 000 to 255 seconds. The default value is 005 seconds.
Card Used (04)
Any output programmed for ’Card Used’ can be active
from 000 to 254 seconds. The default value is 005 seconds. A
pulse time of 000 will cause the output to toggle every time
a card is presented.
NOTE: This output will not activate when used with the
‘Wait for Privileged Card’ feature.