29
Valid entries for the Disarm Delay duration are from 000-
255 minutes. The default setting is 000.
NOTE: Only use with Access Codes, no other disarm
method will support this feature. This feature should not be
used with hand-held wireless keypads
8.5 Dual Users For Disarming
If the partition toggle for 'Dual Usr Dis' (section 5.0) is set to
YES, a second access code is required for disarming.
• Both codes are logged to the event buffer, but the 2nd
code is sent as the opening.
• The 2nd user MUST be assigned to the same partitions
as the 1st user.
• The 2nd access code must be entered within 120 seconds
of the 1st code otherwise the keypad times out to the
idle state.
• During Exit Delay and Entry Delay, both user codes are
still required to disarm the area.
• When performing a "Disarm All' function via the Global
keypad, if any of the areas that the user is assigned to
require dual users, a second code will be required. If the
second user is assigned to all the areas being disarmed,
then the action will be performed successfully. If the
second user is invalid, then the areas that require dual
users will not be turned off. Only the areas that are
assigned to both users will be disarmed.
• When using the 'Disarm All Partitions' in the global
keypad menu, if 'Dual Code' is only enabled on one of
the partitions, a second user code will always be
required to disarm all of your partitions.
NOTE: This feature should not be used with hand-held
wireless keypads.