EasyManua.ls Logo

DSC PC4020 - Access Levels

DSC PC4020
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
•6 Digit Codes
6 Digit Codes6 Digit Codes
6 Digit Codes: If enabled, all access codes will be 6-dig-
its, except for the panel ID code and Downloading
access code. If disabled, all codes will be 4 digits
(default=No).
•Tbl Req Code
Tbl Req CodeTbl Req Code
Tbl Req Code: If enabled, a valid access code must be
entered to silence the trouble beeps from a keypad
(before the condition is restored). If disabled, any key-
press will silence the keypad trouble beeps
(default=No).
•Code Display
Code DisplayCode Display
Code Display: If enabled, access codes will be displayed
while they are being programmed. If disabled, access
codes digits will be represented by ’X’. (Default = No)
Partition Options
Ref # [0100XX01] where XX = Partition 01-08
The following access code options are programmed by par-
tition. Only access codes assigned to the selected partition
will operate according to the following programmed items.
•Bypas Req Code
Bypas Req Code Bypas Req Code
Bypas Req Code - If enabled, the user will be required to
enter an access code in order to bypass a zone on this
partition (default=Yes).
•AutoArm Req Cd
AutoArm Req Cd AutoArm Req Cd
AutoArm Req Cd - If enabled, the user must enter an
access code during the auto-arm pre-alert period in
order to cancel automatic arming. If disabled, pressing
any key will cancel auto-arming (see 8.2 ‘Automatic
Arming‘ (default=No).
NOTE: The Auto Arm Cancellation reporting code, if pro-
grammed, will be sent in either case.
•Cmd. Out Req Cd
Cmd. Out Req Cd Cmd. Out Req Cd
Cmd. Out Req Cd - If enabled, the user will be required
to enter an access code to be able to activate any output
programmed for [*][7][X] Command Output. If dis-
abled, no code will be required. There are eight toggle
options, one for each of the Command Outputs 1-8.
(Default for all = No.)
[*][6] Any Code
[*][6] Any Code [*][6] Any Code
[*][6] Any Code - If enabled, any access code can be
used to access [*] [6] user functions. If disabled, only a
master code will be able to access these functions
(default=No).
Duplicate Code Toggle
When this toggle option is enabled the system will not
allow the programming of duplicate user codes. If a user
code is entered that matches any of the other 1500 users,
Installer, Second Master, Walk Test or Guard code, an error
tone will be generated and the data will not be saved. When
this toggle option is enabled the panel will not perform any
check for duplicates when codes are programmed.
7.10 Access Levels
Ref #: [0100XX05] where XX = Partition 01-08
Access levels allow access codes to be active according to a
schedule. Only one access level can be assigned each user.
See the
Instruction Manual
‘Access Codes’ for details on
access code programming.
Up to 61 access levels can be programmed per partition. To
program an access level, select the access level number 02-
63. Enter the number of the date schedule programmed for
the times and days you wish the access level to follow (see
14.1 ‘Date Schedules‘).
Access level 00 means that the user will never have access.
Access level 01 means that the user will always have access
to a given area.
NOTE: Always program System Master codes as access level
01.

Table of Contents

Other manuals for DSC PC4020

Related product manuals