INTERACTIVE SERVICE MENU
Interactive menus
The “Interactive Services” menu can be used to access information about the TL8803GI module, install or
remove Z-Wave devices and configure or troubleshoot other interactive features.
The menu times out after 20 minutes. Refer to the following tables for the menu options.
Installer programming
Press [*][8][Installer Code][851] to enter Interactive Services menu.
Menu Description
--Alarm.com Module Status Scroll down through the various Alarm.com module information screens.
---Radio Signal level, connection status, roaming status, and errors (if any)
---HSPA Freq. HSPA frequency used by the module.
---SN Module serial number. Needed to create or troubleshoot an Alarm.com account.
---SIM Card
SIM card number. Sometimes needed to troubleshoot an account. Not applicable to
CDMA radios.
---Version
TL8803GI module firmware version and sub-version. Example: 181a; 181 = module
firmware version, a = subversion.
---Advanced - Network Use only when instructed by Alarm.com Technical Support.
--Z-Wave Setup
1
This menu is used to add, remove, and troubleshoot Z-Wave devices and
networks. To control Z-Wave devices via the Alarm.com website and smart phone
apps, you also need to enable Z-Wave services on the account.
--Number of Z-Wave
Devices
2
The total number of Z-Wave devices currently known to the module.
--Add Z-Wave Device
1
Press [*] to enter Z-Wave Add Mode. Make sure the device being added is powered
up and within 3 to 6 feet of the panel. Refer to the manufacturer’s instructions for
button presses required to enroll devices.
---Remove Z-Wave Device
1
Press [*] to remove an existing Z-Wave device, or to “reset” a Z-Wave device that
was previously learned into a different Z-Wave network. Previously enrolled
devices must be reset before they can be enrolled into the module.
---Z-Wave Home ID
1
Press [*] to query the Z-Wave network Home ID. If the ID is 0, verify that the
module has communicated with Alarm.com and that the Alarm.com account is set
up for Z-Wave.
---Extended Range Option Press [*] to enable/disable extended range
---Communications Test Press [*] to perform ADC communication test
User functions
Press [*][6][Master Code] to enter User Functions menu. Then scroll to Interactive Services.
Menu Description
--Alarm.com Module Status See Installer Programming section
---Radio See Installer Programming section
---HSPA Freq. See Installer Programming section
- 21 -