30
[005] System Times
Default Valid entries: [001-255]
030
I_______I_______I_______I Entry Delay 1 (in seconds) and 5.18 “Entry/Exit Delay Options” on page 24)
045
I_______I_______I_______I Entry Delay 2 (in seconds) and 5.18 “Entry/Exit Delay Options” on page 24)
120
I_______I_______I_______I Exit Delay (in seconds) and 5.18 “Entry/Exit Delay Options” on page 24)
004 I_______I_______I_______I Bell Cut-off (in minutes) and 5.13 “Bell” on page 23)
[006] Installer’s Code
(Section 4.1 “Installer’s Programming” )
Default
5555 I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes” )
Default
1234 I_______I_______I_______I_______I
[008] Guard Code (Section 5.1 “Programming Security Codes” )
Default
AAAA
I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.11 “PGM Output Options” )
Programmable Output Options
01 Burglary and Fire Bell Output 16 GSM1000 Support (PGM1 only)
02 For Future Use 17 Away Armed Status
03 Sensor Reset 18 Stay Armed Status
04 For Future Use 19 Command Output #1 ([*][7][1])
05 System Armed Status 20 Command Output #2 ([*][7][2])
06 Ready To Arm 21 For Future Use
07 Keypad Buzzer Follow Mode 22 For Future Use
08 For Future Use 23 For Future Use
09 System Trouble Output (with Trouble options) 24 For Future Use
10 System Event [Strobe (with Event options)] 25 For Future Use
11 System Tamper (all sources: zones, kpd, modules) 26 Battery Test
12 For Future Use 27 Police Code Output
13 For Future Use 28 Holdup Output
14 For Future Use 29 Zone Follower
15 Remote Operation (DLS-3 Support)
NOTE:Output types [03] and [20] cannot be used together on the same system.
Default Default
05 I_______I_______I PGM 1 03 I_______I_______I PGM 2
Program PGM Option Attributes in sections [141] & [142].
[012] Keypad Lockout Options
(Section 5.21 “Keypad Lockout Options” )
NOTE: If Keypad Lockout is active, the panel cannot be dis-
armed with a keyswitch.
Default
000
I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I Lockout Duration (001-255 minutes)