Programming Worksheets: 5.32 Walk Test (Installer)
31
[013] First System Option Code
Default Option ON Off
OFF I________I 1 Normally Closed Loops End-of-Line Resistors
ON
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors
OFF*
I________I 3 For Future Use
ON I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open
OFF
I________I 5 For Future Use
OFF
I________I 6 For Future Use
ON I________I 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown
ON
I________I 8 Troubles are Latching Troubles Follow Restore
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
[014] Second System Option Code
Default Option ON Off
OFF I________I 1 Arm / Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled
OFF
I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm
OFF
I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay
OFF
I________I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay
OFF
I________I 5 Bell Squawk On Trouble No Bell Squawk On Trouble
ON
I________I 6 Audible Exit with Urgency Silent Exit Delay
OFF
I________I 7 Exit Delay Termination Enabled Exit Delay Termination Disabled
OFF
I________I 8 Fire Bell is Continuous Fire Bell Follows Bell Cut-off
[015] Third System Option Code
Default Option ON Off
OFF I________I 1 Fire Keys Enabled Fire Keys Disabled
OFF
I________I 2 Panic Keys Audible (Bell / Beeps) Panic Keys Silent
ON
I________I 3 Quick Exit Enabled Quick Exit Disabled
ON*
I________I 4 Quick Arming Enabled Quick Arming Dis. / Function keys Req. Code
ON
I________I 5 Code Required For Bypassing No Code Required
OFF
I________I 6 Master Code Not Changeable Master Code Changeable
ON
I________I 7 TLM Enabled TLM Disabled
OFF
I________I 8 TLM Audible (Bell) When Armed TLM Trouble Beeps When Armed
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
Default Option ON Off
ON I________I 1 AC Trouble Displayed AC Trouble Not Displayed
OFF
I________I 2 Trouble Light Flashes if AC Fails Trouble Light Does Not Follow AC Status
OFF
I________I 3 Blank Keypad When Not Used Keypad Active Always
ON
I________I
4 Code Required to Remove Kypd Blanking No Code Required
ON I________I 5 Keypad Backlighting is Enabled Keypad Backlighting is Disabled
OFF
I________I 6 Power Save Mode Enabled Power Save Mode Disabled
OFF
I________I 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
OFF
I________I 8 Keypad Tampers Enabled Keypad Tampers Disabled