34
PGM Output Attributes
(Section 5.11 “PGM Output Options” )
Program only the following attributes for the PGM Options listed. All others will be ignored. PGM Options are programmed in
[009]. PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
Section PGM Output 1 2 3 4 5 6 7 8
#Type*
[141] 1 ( )
I________I I________| I________| I________| I________| I________| I________| I________I
[142] 2 ( ) I________I I________| I________| I________| I________| I________| I________| I________I
*Record here based on programming in [009].
[160] Maximum Dialing Attempts to Each Telephone Number
(Section 5.5 “Communicator – Dialing” )
Default: 007 I_______I_______I_______I Valid entries are 001-015 attempts (do not enter 000).
[161] Post Dial Wait for Handshake (All Formats)
(Section 5.5 “Communicator – Dialing” )
Default: 040 I_______I_______I_______I Valid entries are 001-255 seconds
[164] PGM Output Timer
(Section 5.11 “PGM Output Options” )
Default: 005 I_______I_______I_______I Valid entries are 001-255 seconds
Attribute: 1 2 3 4 5
ON
Output enabled True Output Follows Timer Code Req.
OFF
Output disabled Inverted On / Off No Code Req.
PGM Option
[01] Burg. / Fire Bell Y Y
[03] Sensor Reset Y Y N
[05] Armed Status Y Y
[06] Ready To Arm Y Y
[07] Kypd Bzz Follow Y Y
[08] Courtesy Pulse Y Y
[11] System Tamper Y
[12] TLM and Alarm Y
[13] Kiss-off Y
[14] Gnd Strt Pulse Y
[15] Remote Op. Y
[16] GSM1000 Support Y
[17] Away Armed Status Y Y
[18] Stay Armed Status Y Y
[19] Comm. Output #1 Y Y Y Y
[20] Comm. Output #2 Y Y Y N
[21] Comm. Output #3 Y Y Y N
[22] Comm. Output #4 Y Y Y N
[23] Silent 24 Hr Y
[24] Audible 24 Hr Y
[26] Battery Test Y
[27] Police Code Y Y
[28] Holdup Y Y
Attribute:
123456 7 8
PGM Option
ON Serv. req. AC Fail
Disabled
Y
TLM Fault
Disabled
Y
FTC
Disabled
Y
Zone Fault
Disabled
Y
Zone Tmp.
Disabled
Y
Zn. Low Bat.
Disabled
Y
Loss of Clock
Disabled
Y
OFF Disabled
[09] System Trouble Y
ON Burg. Evnt. Fire Evnt. Panic Evnt. Med. Evnt. Supv. Evnt. Priority Evnt. Holdup Evnt. Follows Timer*
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Latched
[10] System Event YYYYYYY N
*If attribute [8] is turned ON, attributes [1-7] must also be turned ON.
ON: Follows Zone Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
OFF: Doesn’t Follow Zone
[29] Zone Follower NNNNNNN N

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC585 and is the answer not in the manual?

DSC PowerSeries PC585 Specifications

General IconGeneral
Partitions1
CommunicatorBuilt-in
Keypads Supported8
PGM Outputs2
Power Supply16.5VAC
Battery Backup12VDC, 4AH
Operating Temperature0°C to 49°C (32°F to 120°F)
HumidityUp to 85% non-condensing
Zones8