6.12 Master Reset
All parameter values are returned to their delivery status (preset values) through a
master reset.
Note
During a master reset all external consumers, e.g. sewing foot lift, must be turned off.
For this reason the 37-pin plug "A" of the machine connection should be unplugged
from the drive controls.
–
Turn the main switch off.
–
Unplug 37-pin plug "
A
" from the drive controls. (See section 6.6)
–
Press the "
P
" key and turn the main switch on.
–
Release the "
P
" key.
–
Enter code number "
1907
". See Chapter 6.10.2.2 and/or 6.10.2.3
–
Press the "
E
" key. The parameter
F-100
is shown.
–
Press the "E" key. The value of the parameter
F-100
is shown.
–
Set the value to
170
.
–
Press the "
P
" key twice.
–
Turn the main switch off.
–
Insert 37-pin plug "
A
". (See section 6.6)
–
Turn the main switch on after a brief wait. All parameters, except 111, 161, 170,
171 and 190 to 193, have the preset values that were set at the factory again.
NOTE !
With a master reset certain parameters, such as e.g.
F-170
(reference position),
F-171
(needle position) and
F-161
(motor direction of turn) are not reset.All parameters which
are set specifically for the machine must be set again as
per the Parameter Sheet.See Chapter 6.11
GB
29