EasyManua.ls Logo

E.T. Systems Drive 600 - BT Button Triggers - Condominium Auto-Close Mode

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Basic operang
features
“BT” Buon triggers.
Condominium auto-close mode.
The BT funcons are the primary full gate opening funcons for motor vehicle access.
There are two ways of acvang the “BT” funcons on this control card. Either via the hardwired BT input or the BT receiver channel.
In Condominium auto-close mode, all BT triggers are treated as open, keep opening, keep open or re-open triggers. The gates will only close once the
BT auto-close mer has med out.
In Condominium auto-close mode the following advanced features are NOT available: - Holiday lock-out and Party mode.
NB! For any auto-close feature to work, a pair of safety infra-red beams must be installed and funconing correctly. If no safety infra-red beams are
installed then the gates will open but not close again.
Acon Response
Momentary BT trigger.
Gate begins
opening.
No buzzer tones.
Momentary BT trigger
while gate is opening.
The trigger is
ignored and the
gate connues
opening.
No buzzer tone.
At full open posion.
Gate stops
and auto-close
mer starts
counng down.
No buzzer tones.
Momentary BT trigger.
Gate remains
open and auto-
close mer
resets.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
At full open posion.
Gate stops
and auto-close
mer starts
counng down.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
At full closed posion. Gate stops. No buzzer tones.
0
0 sec.c.
0
0 sec.c.
0
20 sec.
0
20 sec.
0
20 sec.
Gate closed.