10
Basic operang
features
“BT” Buon triggers.
Condominium auto-close mode.
The BT funcons are the primary full gate opening funcons for motor vehicle access.
There are two ways of acvang the “BT” funcons on this control card. Either via the hardwired BT input or the BT receiver channel.
In Condominium auto-close mode, all BT triggers are treated as open, keep opening, keep open or re-open triggers. The gates will only close once the
BT auto-close mer has med out.
In Condominium auto-close mode the following advanced features are NOT available: - Holiday lock-out and Party mode.
NB! For any auto-close feature to work, a pair of safety infra-red beams must be installed and funconing correctly. If no safety infra-red beams are
installed then the gates will open but not close again.
Acon Response
Momentary BT trigger.
Gate begins
opening.
No buzzer tones.
Momentary BT trigger
while gate is opening.
The trigger is
ignored and the
gate connues
opening.
No buzzer tone.
At full open posion.
Gate stops
and auto-close
mer starts
counng down.
No buzzer tones.
Momentary BT trigger.
Gate remains
open and auto-
close mer
resets.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
At full open posion.
Gate stops
and auto-close
mer starts
counng down.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
At full closed posion. Gate stops. No buzzer tones.
0