Advanced features
Tamper alarms.
Beam tamper in closed posion.
In cases where the safety beams have been tampered with, the safety protocols will sll allow the gates to open but will not allow the gates to close.
This safety feature can be turned into a security risk by anyone with ill intenon. The safety beam input tampering alarm feature gives you a ealry
warning of any tampering that may have occured while you were away from the property. If the gates are in the closed posion and the safety beam
input is trigger for longer than 20 seconds, then the alarm output will become acve. This output would usually be connected to a visual warning
device such as a light or to a zone on the household alarm system.
In the case of a light being used, on approach to the entrance the user is alerted to the aempt to compromise their security. Our advise is that the
user not trigger the gates to open, in this situaon, but rather to connue driving to their nearest armed response standby point or to the nearest
police staon. This way they can ask for an escort onto the property.
Safety beam alarm mode is available in all modes of operaon so long as a set of safety beams is installed.
Acon Response
Safety beam equipment
tampered with while
gates are in the closed
posion.
Alarm output
remains in
standby status.
20 seconds aer safety
beam equipment has
been tampered with.
Alarm output
acvates.
Safety beam equipment
returned to normal
funconing status.
Alarm output
returns to
standby.
Gate closed.
O
0
20 sec.
On/o...
Built in buzzer sounding is
oponal.
On
O
Advanced features
Gate kept open too long alarm.
In a cases where the user would like to be noed of the gate being kept open for longer than a predetermined me period, the gate jammed open
alarm can be setup. The alarm condion will reset to o when the gate is closed again.
Acon Response
Gate prevented from
closing.
Alarm output
remains in
standby status.
Aer programmed gate
jammed open me.
Alarm output
acvates.
Gate returns to full
closed posion.
Alarm output
returns to
standby.
O
0
20 sec.
On/o...
Built in buzzer sounding is
oponal.
On
O