5. It is highly recommended that a set of safety infra-red beams be used in conjuncon with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or gate.
6. Over and above the recommendaon to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automac closing feature. It is recommended that a warning light be ed to any automaon system.
7. The emergency manual release instrucon label must be installed on or adjacent to the emergency manual release mechanism.
Aer installaon - It is the responsibility of the installer to ensure the users:
1. Is procient in the use of the manual emergency release mechanism.
2. Is issued with the documentaon accompanying this product.
3. Understands that the gate or door may not be operated out of clear sight.
4. Ensures that children are kept clear of the gate or door area at all mes, and that children do not play with the remote transmiers
or any xed trigger switches linked to the system.
5. Is instructed not to aempt to repair or adjust the automaon system and to be aware of the danger of connuing to use the
automaon system in an unsafe condion before a service provider aends to it.
6. Is procient in tesng the units safety obstrucon sensing system.
7. Is aware of what to check for with regards to wear and tear that may need to be aended to from me to me by the service
provider.
8. Is aware that a fagued baery may not be disposed of in the general refuse and must be handed in at a baery merchant for safe
disposal. Before removing the baery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the baery must be removed rst.
Technical specicaons.
TECHNICAL SPECIFICATIONS
Technical Data Drive 500 Drive 600
Rated gate mass. 500kg 500kg
Maximum gate travel. 99m 99m
Primary power supply to gate. 16Vac @ 1A 50Hz – 60Hz 220 – 240Vac @ 50Hz – 60Hz
Peak power consumpon at gate. 26W 240W
Electrical class. Class 3 Class 1
Motor voltage. 12Vdc 12Vdc
Motor current. Current limited to 25A. Current limited to 25A.
Duty cycle maximum.
See determining your duty cycle on page 7.
25% with 220Vac present 98% with 220Vac present
Number of operaons on baery reserve.
(Baery health and charge level at me of
power failure dependent. Calculated on a 5m
gate with rolling resistance of <10kgf)
100 using the standard 7Ah baery within
24hrs.
100 using the standard 7Ah baery within
24hrs.
Gate speed.
(Gate load and power supply dependent)
Up to 28m/min. Up to 30m/min.
Rated Load. 300N 300N
Operang temperature range. -10 to 50° C (14F to 122F) -10 to 50° C (14F to 122F)
An-crushing safety sensing. Yes – Electronic gate proling Yes – Electronic gate proling
Auxiliary supply output. 12Vdc @ 500mA 12Vdc @ 500mA
Built in baery charger. Mulple stage auto-calibrang 1A Mulple stage auto-calibrang 1A
Receiver format.
ET BLU MIX © backward compable with ET
BLUE (Rolling code)
ET BLU MIX © backward compable with ET
BLUE (Rolling code)
Receiver frequency. 433.92MHz 433.92MHz
Receiver channels. 4CH (BT, PED, Aux relay, Holiday lock-out) 4CH (BT, PED, Aux relay, Holiday lock-out)
Receiver memory capacity. 1023 users 1023 users
All users can be allowed control of all channels. Yes Yes
Ingress protecon IPX4 IPX4