Example6:Yearlymodeoff,Monthlymodeoff,Pulseselected,OnTime=2008-03-15,OffTime=
****-**-**:OnMarch15,2008thetimeroutputswitchesonforonecycle.Becausethetimerdoesnot
haveamonthlyactionoryearlyaction,thetimeroutputpulsesonlyonetime
atthespecifiedOnTime.
Example7:Yearlymodeon,Monthlymodeoff,Pulseoff,OnTime=2008-12-15,OffTime=
2010-01-07:OnDecember15of2008and2009,thetimeroutputswitchesonandremains
onuntilJanuary7ofthefollowingyear.WhenthetimeroutputturnsoffonJanuary7,2010it
doesNOTturnonagainthefollowingDecember15.
Example8:Yearlymodeon,Monthlymodeon,OnTime=2008-**-01,OffTime=2010-**-