84
3.Confirm'Edit':PressOK
(Ifrequired,enteryourpasswordandconfirmwithOK.)
4.Select'EditPrg':Press or
5.Confirm'EditPrg':PressOK
6.MovethecursortoB2,theinputofQ1:Press
7.ConfirmwithOK.
8.NowreplaceblockB2withblockB1atoutputQ1.Theprocedure:
SelecttheBNlist:Press or
AccepttheBNlist:PressOK
Select'B1':Press or
Apply'B1':PressOK
Result:BlockB2isdeleted,becauseitisnolongerusedinthecircuit.BlockB1hasreplaced
5.6Memoryspaceandcircuitprogramsize
ThesizeofacircuitprograminxLogicislimitedbythememoryspace(memoryusedbytheblocks).
Upto512blockscanbeusedinxLogic.
Indicationofavailablememoryspace
xLogicshowsyoutheamountoffreememoryspace.
Proceedasfollows:
1.SwitchxLogictoprogrammingmode
(asareminder,refertothetopic"ThefourgoldenrulesforoperatingxLogic".
2.Select'Edit':Press or
3.Accept'Edit':PressOK
4.Select'Memory?':Press or