166
AQ.
0oninputENswitches0to
theoutputAQ.
Inputs S1
and S2
S1andS2(selectors)for
selectingtheanalogvalueto
beissued.
S1=0andS2=0:Thevalue
1isissued
S1=0andS2=1:Thevalue
2isissued
S1=1andS2=0:Thevalue
3isissued
S1=1andS2=1:Thevalue
4isissued
Parameter V1...V4:Analogvalues
(Value)thatwillbeissued.
Valuerange:
-32768...+32767
p:Numberofdecimalplaces
valuerange:0,1,2,3
Output AQ Analogoutput
ValuerangeforAQ:
-32768...+32767
ParametersV1V4
ThevaluesforV1V4canbeprovidedbythevalueofanotheralready-programmedfunction:
Analogcomparator:Ax Ay
Analogtrigger:Ax
Analogamplifier:Ax
Analogmultiplexer:AQ
Analogramp:AQ
Analogmath:AQ
PIcontroller:AQ
Datalatchingrelay:AQ
Up/Downcounter:Cnt
TimingDiagram