191
analogOutputAQisresetifSandRarebothset(resethas
priorityoverset).
Output AQ Analogoutput
ValuerangeforAQ:-32768...+32767
Example
WhenI1turntoHIGH,thevalueofAI2willbesavedtomemoryandreturnittoAQ1
asfollows:
WhentheI3turnstoHIGH,thevalueofthisfunctionblockwillberesetto0.