Outputs Menu
Page 40
PIR Set Latch (25)
Active when the system is set. Inactive when the system is unset or an alarm
condition occurs. The output is active for one second when a reset is performed or
when the control unit leaves installer mode.
Note: By default this output is at +12V when active and 0V when inactive. Use the
Inverted attribute if you wish to change this behaviour.
Shock Sensor Reset (26)
The output deactivates five seconds after the setting procedure has started (such as
five seconds after an instant set or five seconds after the exit timer starts). Use this
output to reset shock sensors (for example, the "Viper"). The normal state of this
output is active.
Walk Test (27)
Active when a user starts Installer or User Walk Tests. Also active during the time
between silencing and resetting the system. This output can be used on movement
detectors that are able to switch off the Walk Test lamp in any state other than a
Walk Test.
Smoke Sensor Reset (28)
This output is active (0V) all the time except when a user acknowledges a fire alarm.
After which, the control unit deactivates the output for three seconds. This output
type is designed to be connected to low-voltage smoke detector reset terminals.
Note: Some smoke detectors (for example the Texecom OH 4W) require that the
user reset the system twice after an alarm. This is to give the detector time to close
its alarm contacts after the reset pulse.
24 Hour Alarm (29)
Active when the control unit starts a 24-hour alarm.
Setting Complete (30)
Active when the control unit finishes setting. Active for 10 seconds.
Unset Complete (31)
Active when someone unsets the system or disarms it after an alarm. The output is
active for 10 seconds.
Full Set Ready (32)
Active when no detectors are reporting “alarm” signals.
Full Set (33)
Active when the system is full set.
Part Set (34)
Active when the system is part set.
Part Set B (35)
Active when setting Part Set B. Deactivated on unsetting Part Set B.
This output type is available only if a zone has the Part Set B attribute set to On.
Part Set C (36)
Active when setting Part Set C. Deactivated on unsetting Part Set C.
This output type is available only if a zone has the Part Set C attribute set to On.
Part Set D (37)
Active when setting Part Set D. Deactivated on unsetting Part Set D.
This output type is available only if a zone has the Part Set D attribute set to On.