System Options Menu
Page 52
Installer Timeout
The installer is automatically logged out of the Installer menu if there is no activity after the
specified period.
Service Date
This option allows you to specify the date when the next maintenance service of the
system is due. If Service Banner is enabled, the message "SERVICE REQUIRED" is
displayed at keypads up to four hours after the start of the Service Date.
Service Banner
Enabling this option allows the "SERVICE REQUIRED" message to be displayed at
keypads on the date specified by Service Date.
Confirmation
The options in the Confirmation menu depend on the Confirmation Mode you select.
Confirmation Mode
The options in Confirmation Mode depend on the country selected during the initial power
up (see page 19):
If the country is anywhere other than the UK, Basic confirmation mode is always
used.
If the country is the UK, Confirmation Mode contains three options: Basic, DD243
and BS8243.
The setting for Confirmation Mode determines the events the control unit requires to create
a "confirmed alarm":
Basic (default and only setting if the country is not the UK) A confirmed alarm is
generated when a second zone alarm is activated while the system is in an alarm
state.
BS8243 or DD243 (if the country is the UK) A confirmed alarm is generated when
a second zone alarm is triggered within the period of the confirmation timer setting
(Confirmation Time or HUA Confirm Time, as applicable). If you select either of
these options, additional options are displayed to define the meaning of a confirmed
alarm.
If the first ("unconfirmed") alarm is caused by the expiry of the entry timer, then for:
DD243 A further two zones that are not on the entry route must be triggered to
generate a Burg Confirmed Alarm.
BS8243 One zone not on the entry route must be triggered to generate a Burg
Confirmed Alarm.

Table of Contents

Other manuals for Eaton Scantronic i-on10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Scantronic i-on10 and is the answer not in the manual?

Eaton Scantronic i-on10 Specifications

General IconGeneral
BrandEaton
ModelScantronic i-on10
CategorySecurity System
LanguageEnglish

Related product manuals