Outputs Menu
Page 42
Courtesy Light (45)
Active when the entry or exit timer is running. The control unit activates this output
when the entry or exit time starts, and deactivates the output 10 seconds after the
entry or exit time stops.
Installer on Site (46)
The control unit activates the output when an installer enters the Installer menu, and
deactivates the output once the installer has exited the Installer menu.
Duress Code (47)
Active when a user keys in a Duress code, and deactivates the output when a user or
engineer resets the system.
HUA Confirmed Alarm (48)
Although this output type is always available in the menu, it operates only when
BS8243 is enabled.
Active when there is an HUA Confirmed Alarm (see page 52).
Lockset Unlocked (49)
The control unit activates the output when the Lock Set zone is activated, and
deactivates the output when a Lock Set zone is deactivated.
Burg Confirm timer (50)
Active when a Burg confirmation timer is running. Inactive when the timer stops.
Although this output type is always available in the menu, it operates only when
BS8243 or DD243 is enabled.
HUA Confirm Timer (51)
Active when an HUA confirmation timer is running. Inactive when the timer stops.
Although this output type is always available in the menu, it operates only when
BS8243 is enabled.
Rearmed (52)
The control unit activates the output if the system re-arms at least once after the user
armed it.
If Confirmation Mode (page 52) is set to BS8243 or DD243, the control unit activates
the output as it rearms the system after the confirmation timer expires.
If Confirmation Mode is set to Basic, the control unit activates the output as it rearms
the system when the bell/siren time expires.
The control unit deactivates the output when a user or installer resets the system.
Burg Confirmed Alarm (53)
Active when there is a Burg Confirmed Alarm (see page 52).
The control unit deactivates the output when a user or engineer resets the system.
Entry Only (71)
Active when the system is in entry mode.
Exit Only (72)
Active when the system is in exit mode. Note this output will NOT activate if the
system uses Instant Set exit mode.
Chime Tone Mimic (73)
Active when any zone with a chime attribute is active.