EasyManuals Logo

Eaton Vickers V Series User Manual

Eaton Vickers V Series
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11
20V Performance Characteristics
DELIVERY - l/min (US gpm)
0
400 800 1200 1600 2000
7,57 (2.00)
15 (4.00)
23 (6.00)
30,3 (8.00)
38 (10.0)
45 (12.0)
53 (14.0)
61 (16.0)
SPEED - RPM
bar (psi) Code
7 (100)
70 (1000)
160 (2300)
207 (3000)
9
7 (100)
70 (1000)
140 (2000)
2
0
400 800 1200 1600 2000
SPEED - RPM
bar (psi) Code
207 (3000) 9
140 (2000) 2
70 (1000) 2
140 (2000) 9
7,5 (10)
0
11,2 (15)
15 (20)
30 (40)
INPUT - kw (hp)
Typical flows at 50°C (120°F), 10W oil (26cSt) - (128 SUS),
0 psi inlet at specified speeds
7 (100) 9
7 (100) 2
20V Cartridge Performance
Codes 2 and 9 Displacement
Codes 2 and 9 Input kw (hp)
3,73 (5)
3,73 (5)
7,5 (10)
18,6 (25)
22,4 (30)
26,1 (35)
70 (1000) 9