10
20V Performance Characteristics
DELIVERY - l/min (US gpm)
0
400 800 1200 1600 2000
10 (2.64)
20 (5.28)
30 (7.93)
40 (10.58)
50 (13.21)
60 (15.85)
70 (18.49)
80 (21.13)
SPEED - RPM
bar (psi) Code
7 (100)
70 (1000)
160 (2300)
12
7 (100)
70 (1000)
140 (2000)
210 (3000)
5
0
400 800 1200 1600 2000
SPEED - RPM
bar (psi) Code
160 (2300) 12
140 (2000) 5
70 (1000) 12
210 (3000) 5
70 (1000) 5
4 (5.36)
8 (10.73)
12 (16.09)
16 (21.46)
20 (26.82)
24 (32.18)
INPUT - kw (hp)
Typical flows at 50°C (120°F), 10W oil (26cSt) - (128 SUS),
0 psi inlet at specified speeds
7 (100) 12
7 (100) 5
20V Cartridge Performance
Codes 5 and 12 Displacement
Codes 5 and 12 Input kw (hp)