EasyManua.ls Logo

Eccotemp SHLX - Page 21

Eccotemp SHLX
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Designed in
Summerville, SC
Support: Support.Eccotemp.com Shop Online: www.Eccotemp.com Phone: 866-356-1992
20
20
Support: Support.Eccotemp.com Shop Online: www.Eccotemp.com Phone: 866-356-1992
PLEASE NOTE: SH12
-
A IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECTED TO CHANGE WITHOUT NOTICE.
PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
English
Maintain the following clearances to any opening
in any building
Illustration
Vent Clearances When
Heater is Installed Indoors
4’ below, 4’ horizontally from, or 1’ above
any door, operable window, or gravity air
inlet into any building.
3’ above any forced air inlet within 10’.
Installation
VENTING CONT.
D
E
B
B
B
B
L
V
V
V
V
F
C
A
J
V
V
M
I
K
A
V
G
V
VENT TERMINAL AIR SUPPLY INLET
AREA WHERE TERMINAL
IS NOT PERITTED
INSIDE CORNER
DETAIL
H
Vent Termination Clearances
for Non-Direct Vent Installations in the US and Canada
FIXED
CLOSED
OPERABLE
OPERABLE
FIXED
CLOSED
B
Clearance Requirements from Vent Terminations to Building Openings
*All clearance requirements are in accordance with ANSI Z21.10.3a-2017 and the National Fuel Gas Code, ANSI Z223.1.
A) A minimum clearance value determined by testing in accordance with clause 5.20, or;
B) A reference to the following foot note:
“Clearance in accordance with local installation codes and the requirements of the gas supplier.”
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single
family dwellings and serves bot dwellings.
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the
oor.
NOTES:
1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code
2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code
4’
4’
1’
3’

Related product manuals